After rebooting, Advanced Monitoring status does not consistently start. About every other reboot, Advanced Monitoring will show "enabled". If after rebooting the status shows "disabled" rebooting again is the only option.
Applies to: All version of DirectAudit installed on Red Hat and CentOS operating systems.
Problem: After rebooting systems with DirectAudit installed, Advanced Monitoring status does not consistently start.
Cause: An unexpected error occurs upon reboot causing Advanced Monitoring not to start upon system reboot.
Resolution: This issue is fixed in Centrify Server Suite 2017.1 but can be worked around with the following procedure: run service auditd restart and then rundacontrol -m